RHEV Implementation


Table of Contents
  Basic prerequisite and Process..............................................................................................................1
     Prerequisite.......................................................................................................................................1
     Process..............................................................................................................................................1
  LLD.......................................................................................................................................................2
  Data Center Creation and Configuration...............................................................................................3
  Cluster Configuration............................................................................................................................3
  Host Configuration................................................................................................................................4
  Host Power Management Configuration...............................................................................................5
  Storage Configuration...........................................................................................................................5
  Attaching the ISO Domain....................................................................................................................6
  Creation of Networks and configuration...............................................................................................7
  Host Network setup with bond and VLAN...........................................................................................8
  Testing with Virtual M/c Creation.........................................................................................................8


Basic prerequisite and Process


Prerequisite
   •    Get the Server Rack Mounted and Network Cabling done
    • Update the Bios
    • Get the Network Port connected as per the earlier configurations of 1 G *2 and 10 G *2
    • Get the Network switches aligned with LACP configured for 1G and 10 G ports
    • Get the Storage Connected via Switch to HBA cards and Project LUNS as per the design
    • Get the ILO / DRAC Connected and Configured with IP and Accessibility .
    • Get ISO downloaded from Redhat Portal for RHEV -H ( Version needs to be checked from
      other Hosts)
    • Physical Assistance of booting via RHEV-H .

Process
   •    Ensure all prerequisite in place including Network Cards , Switch LACP etc Configuration ,
        Storage Projection and visibility , Network Reach-ability etc
   •    Build a New Data center on RHEV
   •    Build the compatible Cluster with cluster name
   •    Install RHEV -H On the Host with provided RHEV-H 4.0 ISO
   •    Test DRAC Connectivity and Fencing .

   •   Add installed host in the Newly build Cluster . ( Do not add Power Fence while Adding ,
       Should be configured once 2 hosts are added )
   •   Configure Power management with idrac7 as RHEV fence.
   •   Once Hosts are configured , Storage will be Visible in the cluster . Configure Storage as FC
       based Storage .
   •   Share the ISO Domain from old datacenter to this newly created datacenter
   •   Add Networks for DMZ and Data along with already created ovirtmgm
   •   Create Bonds for the Individual host and add to the right network .
   •   Now create test VM with pre-uploaded ISOs and test for Live Migration and Host failure .


LLD

                       Connected
                         to N/W
              Port       Switch
Server Ports Type         Port#  VLAN Subnet         IP            Gateway      DNS
Server1                Server
                       Farm 1/0/       172.18.103.0/                            172.18.101.14,
        iDRAC Ethernet SW1 37 iLO   10324            172.18.103.27 172.18.103.1 15
                          Server
                          Farm 1/0/      172.18.102.0/                            172.18.101.14,
          Port 3 Ethernet SW1 6 Mgmt 102 24            172.18.102.27 172.18.102.1 15
                                   Data
                          DMZ 1/0/ (DMZ     172.18.201.0/                            172.18.101.14,
          Port 4 Ethernet SW1 10 )      201 26            172.18.201.54 172.18.201.1 15
          Slot1/          Core 1/0/ Data
          port1    FC 10G SW1 7 (MZ)               172.18.101.0/                            172.18.101.14,
                                             101                 172.18.101.60 172.18.101.1
          Slot2/          Core 2/0/ Data           24                                       15
          port1    FC 10G SW2 7 (MZ)
          Slot3/               port          N/
          port1    FC 10G SAN1 14 N/A        A N/A              N/A             N/A          N/A
          Slot4/               port
          port1    FC 10G SAN2 14 N/A        N/AN/A             N/A            N/A           N/A
Server2                  Server
                         Farm 1/0/               172.18.103.0/                            172.18.101.14,
          iDRAC Ethernet SW1 38 iLO           10324            172.18.103.28 172.18.103.1 15
          Port 3 Ethernet Server 1/0/ Mgmt 102 172.18.102.0/ 172.18.102.28 172.18.102.1 172.18.101.14,
                          Farm 8               24                                       15

                          SW1
                                 Data
                        DMZ 1/0/ (DMZ     172.18.201.0/                            172.18.101.14,
        Port 4 Ethernet SW1 11 )      201 26            172.18.201.55 172.18.201.1 15
        Slot1/          Core 1/0/ Data
        port1    FC 10G SW1 8 (MZ)                 172.18.101.0/                            172.18.101.14,
                                             101                 172.18.101.61 172.18.101.1
        Slot2/          Core 2/0/ Data             24                                       15
        port1    FC 10G SW2 8 (MZ)
        Slot3/               port            N/
        port1    FC 10G SAN1 15 N/A          A N/A              N/A            N/A         N/A
        Slot4/               port
        port1    FC 10G SAN2 15 N/A         N/AN/A              N/A           N/A          N/A


Data Center Creation and Configuration
New Data center Name is Training-DC and compatible for RHEV 3.6 Version


Cluster Configuration
Follow the “Guide me” option to create cluster

Host Configuration
Please have RHEV-H installed on the Host with one basic Network / IP configured .

Host Power Management Configuration
Once minimum 2 hosts are added then fencing can be configured


Storage Configuration
Once hosts are added , Storage is visible . So discovered FC type storage with all the projected LUN.

Attaching the ISO Domain
For New VM configuration you need to have ISO domain . This Domain is already configured for old
data center ( default ) . This ISO domain can be shared and attached with New data center named
Training-DC .

Creation of Networks and configuration
As there are 3 Networks Available , Management , Data and DMZ , Need to be named and created .

Host Network setup with bond and VLAN
As initial Host network configuration was simple and bond was not configured , Now Bonds , VLAN
and Network can be configured for the Hosts .


Testing with Virtual M/c Creation
You can create any VM , Windows or Linux vis the ISO already available in ISO domain . Once VM is
created , testing can be done for Live Migration and Host Failure .